Victron BatteryProtect 12/24V-100A

The BatteryProtect safeguards your battery by automatically disconnecting non-essential loads before the battery becomes dangerously discharged or too weak to start the engine.

12/24V Auto-Ranging
  • Automatically detects whether the system is 12V or 24V.
Easy Programming
  • Set custom engage/disengage voltage levels.
  • A clear seven-segment display shows which setting is selected.
Optimised for Li-ion Batteries
  • Includes a special mode for Li-ion systems, allowing control via the VE.Bus BMS.
  • Can also function as a charge interrupter between a charger and a Li-ion battery (see manual for wiring diagram).
Ultra-Low Current Consumption
  • Particularly important for Li-ion batteries after a low-voltage shutdown. See the Li-ion battery datasheet and VE.Bus BMS manual for details.
Over-Voltage Protection
  • Automatically disconnects loads if DC voltage rises above 16V (12V systems) or 32V (24V systems), preventing damage to sensitive equipment.
Ignition Proof
  • Uses MOSFET switching instead of relays—no sparks.
Delayed Alarm Output
  • Alarm triggers only if voltage remains below the disconnect threshold for more than 12 seconds, preventing false alarms during engine cranking.
  • Short-circuit proof open collector output (max. 50 mA) for driving a relay, LED, or buzzer.
Delayed Disconnect & Reconnect
  • Loads disconnect 90 seconds after the alarm activates, unless voltage recovers within that time.
  • Loads automatically reconnect 30 seconds after voltage rises above the preset reconnect level.